RO flux and recovery

Recovery, concentrate flow, average flux and concentration factor of a reverse osmosis system.

Example values. Replace them with your data.

Recovery—%
Average flux—L/m²·h
Concentrate flow—m³/h
Concentrate / feed concentration—×

Formula
Y = Qp / Qf
Qc = Qf − Qp
J = Qp / (N × S)
Cc / Cf = [1 − Y(1 − R)] / (1 − Y)
Sources
Limits and assumptions
  • Flux is averaged over the whole system. Lead elements run at higher flux than tail elements.
  • The concentration ratio uses one average rejection value. It does not include concentration polarization at the membrane surface.
  • Allowed flux depends on the feed water source and the membrane. Check the design limits in the manufacturer guidelines. They are not built into this calculator.
  • The example values are for illustration only. Take the active area from the element datasheet.